SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "swepub ;pers:(Larsson Anders);pers:(Hansson Lars Olof)"

Sökning: swepub > Larsson Anders > Hansson Lars Olof

  • Resultat 1-10 av 37
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Larsson, Anders, et al. (författare)
  • Circadian variability of cystatin C, creatinine, and glomerular filtration rate (GFR) in healthy men during normal sleep and after an acute shift of sleep.
  • 2008
  • Ingår i: Chronobiol Int. - : Informa UK Limited. - 1525-6073 .- 0742-0528. ; 25:6, s. 1047-61
  • Tidskriftsartikel (refereegranskat)abstract
    • Circadian variability of cystatin C, creatinine, and glomerular filtration rate (GFR) in healthy men during normal sleep and after an acute shift of sleep.Larsson A, Akerstedt T, Hansson LO, Axelsson J.Section of Clinical Chemistry, Department of Medical Sciences, Uppsala University, Uppsala, Sweden. anders.larsson@akademiska.seThe estimation of the glomerular filtration rate (GFR) is essential for the evaluation of patients with kidney disease and for the treatment of patients with medications that are eliminated by the kidneys. Plasma cystatin C has been shown in several studies to be superior to plasma creatinine for the estimation of GFR. However, there is limited information on the circadian variation of cystatin C and estimated GFR using cystatin C (eGFR(CystC)) or "The Modification of Diet in Renal Disease Study" (MDRD) (eGFR(MDRD)) equations. We studied the circadian variation of cystatin C and creatinine during night- and day-sleep conditions in seven healthy volunteers. Serum samples were collected every hour (48 samples per individual) to evaluate the effect of different sampling times on the test results. The median intra-individual coefficients of variations for the studied markers were 4.2% for creatinine, 4.7% for eGFR(MDRD), 5.5% for cystatin C, and 7.7% for eGFR(CystC). Neither cystatin C nor creatinine differed significantly between the night- and day-sleep conditions. Cystatin C differed significantly with time of day (p=.0003), but this was not the case for creatinine (p=.11). The circadian variation of cystatin C was minor. Small but significant increases in creatinine values and a decrease of eGFR(MDRD) were observed after food intake. Thus, cystatin C and creatinine sampling does not have to be restricted to specific times of the day.
  •  
2.
  • Gustafsson, Johanna, et al. (författare)
  • Predictors of the first cardiovascular event in patients with systemic lupus erythematosus : a prospective cohort study
  • 2009
  • Ingår i: Arthritis Research & Therapy. - : Springer Science and Business Media LLC. - 1478-6354 .- 1478-6362. ; 11:6, s. R186-
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION :Cardiovascular disease (CVD) is a major cause of premature mortality among Systemic lupus erythematosus (SLE) patients. Many studies have measured and evaluated risk factors for premature subclinical atherosclerosis, but few studies are prospective and few have evaluated risk factors for hard endpoints, i.e. clinically important cardiovascular events (CVE). We investigated the impact of traditional and lupus associated risk factors for the first ever CVE in a longitudinal cohort of SLE patients.METHODS : A total of 182 SLE patients (mean age 43.9 years) selected to be free of CVE were included. Cardiovascular and autoimmune biomarkers were measured on samples collected after overnight fasting at baseline. Clinical information was collected at baseline and at follow up. End point was the first ever CVE (ischemic heart, cerebrovascular or peripheral vascular disease or death due to CVD). Impact of baseline characteristics/biomarkers on the risk of having a first CVE was evaluated with Cox regression.RESULTS :Follow up was 99.5% after a mean time of 8.3 years. Twenty-four patients (13%) had a first CVE. In age-adjusted Cox regression, any positive antiphospholipid antibody (aPL), elevated markers of endothelial activation (von Willebrand factor (vWf), soluble vascular cellular adhesion molecule-1 (sVCAM-1)) and fibrinogen predicted CVEs. Of SLE manifestations, arthritis, pleuritis and previous venous occlusion were positively associated with future CVEs while thrombocytopenia was negatively associated. Among traditional risk factors only age and smoking were significant predictors. In a multivariable Cox regression model age, any positive aPL, vWf and absence of thrombocytopenia were all predictors of the first CVE.CONCLUSIONS : In addition to age, positive aPL, biomarkers indicating increased endothelial cell activity/damage, and absence of thrombocytopenia were independent predictors of CVEs in this prospective study. Our results indicate that activation of the endothelium and the coagulation system are important features in SLE related CVD. Furthermore, we observed that the risk of CVEs seems to differ between subgroups of SLE patients.
  •  
3.
  • Gustafsson, Johanna, et al. (författare)
  • Risk factors for cardiovascular mortality in patients with systemic lupus erythematosus, a prospective cohort study
  • 2012
  • Ingår i: Arthritis Research & Therapy. - : Springer Science and Business Media LLC. - 1478-6354 .- 1478-6362. ; 14:2, s. R46-
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION:Systemic Lupus Erythematosus (SLE) is a chronic autoimmune disease. Cardiovascular disease (CVD) is common and a major cause of mortality. Studies on cardiovascular morbidity are abundant, whereas mortality studies focusing on cardiovascular outcomes are scarce. The aim of this study was to investigate causes of death and baseline predictors of overall (OM), non-vascular (N-VM), and specifically cardiovascular (CVM) mortality in SLE, and to evaluate Systematic coronary risk evaluation (SCORE).METHODS:208 SLE patients were included 1995-1999 and followed up after 12 years. Clinical evaluation, CVD risk factors, and biomarkers were recorded at inclusion. Death certificates and autopsy protocols were collected. Causes of death were divided into CVM (ischemic vascular and general atherosclerotic diseases), N-VM and death due to pulmonary hypertension. Predictors of mortality were investigated using multivariable Cox regression. SCORE and standardized mortality ratio (SMR) were calculated.RESULTS: During follow-up 42 patients died at mean age of 62 years. SMR 2.4 (CI 1.7-3.0). 48% of deaths were caused by CVM. SCORE underestimated CVM but not to a significant level. Age, high cystatin C levels and established arterial disease were the strongest predictors for all- cause mortality. After adjusting for these in multivariable analyses, only smoking of traditional risk factors, high soluble vascular cell adhesion molecule-1 (sVCAM-1), high sensitivity C-reactive protein (hsCRP), anti-beta2 glycoprotein-1 (abeta2GP1) and any antiphospholipid antibody (aPL) among biomarkers, remained predictive of CVM.CONCLUSION:With the exception of smoking, traditional risk factors do not capture the main underlying risk factors for CVM in SLE. Rather, cystatin C levels, inflammatory and endothelial markers, and anticardiolipin antibodies (aCL) differentiate patients with favorable versus severe cardiovascular prognosis. Our results suggest that these new biomarkers are useful in evaluating the future risk of cardiovascular mortality in SLE patients.
  •  
4.
  • Nilsen, Tom, et al. (författare)
  • A novel turbidimetric immunoassay for fecal calprotectin optimized for routine chemistry analyzers
  • 2017
  • Ingår i: Journal of clinical laboratory analysis (Print). - : Wiley. - 0887-8013 .- 1098-2825. ; 31:4
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Fecal calprotectin assays are widely used to exclude inflammatory bowel disease (IBD) in patients with suspected IBD. A problem with the fecal calprotectin assays is the rather long test-turnaround times. A particle enhanced turbidimetric immunoassays (PETIA) for fecal calprotectin would reduce test-turnaround times and would permit more laboratories to perform the measurements. The aim of this study was to evaluate a new feces calprotectin PETIA.METHOD: Using routine fecal samples the feces calprotectin PETIA was validated on two chemistry analyzers, Mindray BS-380 and Cobas 501.RESULTS: The assay is linear in the range 11-2000 μg/g, with a limit of quantitation of approximately 10 μg/g. No antigen excess hook effect was observed up to 10 000-15 000 μg/g depending on the instrument used. The turbidimetric method showed a good agreement with the Bühlmann ELISA. The total coefficient of variation was 3%-8% in the 50-100 μg/g range.CONCLUSION: The fecal calprotectin PETIA, fCal Turbo, is well suited for rapid analysis of fecal calprotectin on Mindray BS-380 or Cobas 501 clinical chemistry analyzers. The test results are commutable with Bühlmann fecal MRP8/14 ELISA.
  •  
5.
  •  
6.
  • Rollborn, Niclas, et al. (författare)
  • Analysis of HbA1c on an automated multicapillary zone electrophoresis system.
  • 2017
  • Ingår i: Scandinavian Journal of Clinical and Laboratory Investigation. - : Informa UK Limited. - 0036-5513 .- 1502-7686. ; 77:1, s. 15-18
  • Tidskriftsartikel (refereegranskat)abstract
    • Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R(2 )= .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R(2 )= .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.
  •  
7.
  • Grubb, Anders, et al. (författare)
  • Generation of a new cystatin C-based estimating equation for glomerular filtration rate by use of 7 assays standardized to the international calibrator
  • 2014
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 60:7, s. 974-986
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Many different cystatin C-based equations exist for estimating glomerular filtration rate. Major reasons for this are the previous lack of an international cystatin C calibrator and the nonequivalence of results from different cystatin C assays.METHODS:Use of the recently introduced certified reference material, ERM-DA471/IFCC, and further work to achieve high agreement and equivalence of 7 commercially available cystatin C assays allowed a substantial decrease of the CV of the assays, as defined by their performance in an external quality assessment for clinical laboratory investigations. By use of 2 of these assays and a population of 4690 subjects, with large subpopulations of children and Asian and Caucasian adults, with their GFR determined by either renal or plasma inulin clearance or plasma iohexol clearance, we attempted to produce a virtually assay-independent simple cystatin C-based equation for estimation of GFR.RESULTS:We developed a simple cystatin C-based equation for estimation of GFR comprising only 2 variables, cystatin C concentration and age. No terms for race and sex are required for optimal diagnostic performance. The equation, [Formula: see text] is also biologically oriented, with 1 term for the theoretical renal clearance of small molecules and 1 constant for extrarenal clearance of cystatin C.CONCLUSIONS:A virtually assay-independent simple cystatin C-based and biologically oriented equation for estimation of GFR, without terms for sex and race, was produced.
  •  
8.
  • Björk, Jonas, et al. (författare)
  • Accuracy of GFR estimating equations combining standardized cystatin C and creatinine assays: a cross-sectional study in Sweden
  • 2015
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 53:3, s. 403-414
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The recently established international cystatin C calibrator makes it possible to develop non-laboratory specific glomerular filtration rate (GFR) estimating (eGFR) equations. This study compares the performance of the arithmetic mean of the revised Lund-Malmo creatinine and CAPA cystatin C equations (MEAN(LM-REV+CAPA)), the arithmetic mean of the Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI) creatinine and cystatin C equations (MEAN(CKD-EPI)), and the composite CKD-EPI equation (CKD-EPICREA+CYSC) with the corresponding single marker equations using internationally standardized calibrators for both cystatin C and creatinine. Methods: The study included 1200 examinations in 1112 adult Swedish patients referred for measurement of GFR (mGFR) 2008-2010 by plasma clearance of iohexol (median 51 mL/min/1.73 m(2)). Bias, precision (interquartile range, IQR) and accuracy (percentage of estimates +/- 30% of mGFR; P-30) were compared. Results: Combined marker equations were unbiased and had higher precision and accuracy than single marker equations. Overall results of MEAN(LM-REV+CAPA)/MEAN(CKD-EPI)/CKD-EPICREA+CYSC were: median bias -2.2%/-0.5%/-1.6%, IQR 9.2/9.2/8.8 mL/min/1.73 m(2), and P-30 91.3%/91.0%/91.1%. The P-30 figures were about 7-14 -percentage points higher than the single marker equations. The combined equations also had a more stable performance across mGFR, age and BMI intervals, generally with P-30 >= 90% and never <80%. Combined equations reached P-30 of 95% when the difference between eGFR(CREA) and eGFR(CYSC) was <10% but decreased to 82% at a difference of >= 40%. Conclusions: Combining cystatin C and creatinine assays improves GFR estimations with P-30 >= 90% in adults. Reporting estimates of both single and combined marker equations in clinical settings makes it possible to assess the validity of the combined equation based on the agreement between the single marker equations.
  •  
9.
  • Nyman, Ulf, et al. (författare)
  • The revised Lund-Malmo GFR estimating equation outperforms MDRD and CKD-EPI across GFR, age and BMI intervals in a large Swedish population
  • 2014
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 52:6, s. 815-824
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The performance of creatinine-based glomerular filtration rate (GFR) estimating equations may vary in subgroups defined by GFR, age and body mass index (BMI). This study compares the performance of the Modification of Diet in Renal Disease (MDRD) study and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations with the revised Lund-Malmo equation (LM Revised), a new equation that can be expected to handle changes in GFR across the life span more accurately. Methods: The study included 3495 examinations in 2847 adult Swedish patients referred for measurement of GFR (mGFR) 2008-2010 by plasma clearance of iohexol (median 52 mL/min/1.73 m(2)). Bias, precision [interquartile range (IQR)] and accuracy [percentage of estimates +/- 10% (P-10) and +/- 30% (P-30) of mGFR] were compared. Results: The overall results of LM Revised/MDRD/CKD-EPI were: median bias 2%/8%/11%, IQR 12/14/14 mL/min/1.73 m(2), P-10 40%/35%/35% and P-30 84%/75%/76%. LM Revised was the most stable equation in terms of bias, precision and accuracy across mGFR, age and BMI intervals irrespective of gender. MDRD and CKD-EPI overestimated mGFR in patients with decreased kidney function, young adults and elderly. All three equations overestimated mGFR and had low accuracy in patients with BMI <20 kg/m(2), most pronounced among men. Conclusions: In settings similar to the investigated cohort LM Revised should be preferred to MDRD and CKD-EPI due to its higher accuracy and more stable performance across GFR, age and BMI intervals.
  •  
10.
  • Flodin, Mats, et al. (författare)
  • Evaluation of Dade Behring N Latex Cystatin C reagent on Abbott ci8200
  • 2006
  • Ingår i: Upsala Journal of Medical Sciences. - 0300-9734 .- 2000-1967. ; 111:2, s. 209-213
  • Tidskriftsartikel (refereegranskat)abstract
    • Plasma cystatin C has been shown in several studies to be superior to plasma creatinine for estimation of glomerular filtration rate (GFR). Reporting cystatin C results in mL/min using conversion formulas for transforming cystatin C expressed as mg/L to GFR expressed as mL/min has greatly facilitated the clinical use of the marker. At our hospital we have an increasing demand for cystatin C and at present we perform over 1,400 cystatin C analyses a month. The test is available at all hours. This in combination with the volume emphasises the need to have the assay close to the routine chemistry instrument to reduce handling time per test and time to report test results. We have thus evaluated the Dade Behring N Latex Cystatin C assay (Dade Behring, Deerfield, IL, USA) on Architect 68200 (Abbott Laboratories, Abbott Park, IL, USA). The nephelometric method on the ProSpec (Dade Behring) and the turbidimetric method on Architect 68200 showed very good agreement (y = 1.0072x + 0.0042; R-2 = 0.987). Accordingly, running the cystatin C analyses on a chemistry instrument (Architect 68200) would be proper to increase the availability of the analysis and reduce turnaround times.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 37
Typ av publikation
tidskriftsartikel (36)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (34)
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Flodin, Mats (10)
Grubb, Anders (5)
Åkerfeldt, Torbjörn (4)
Nordin, Gunnar (4)
visa fler...
Björk, Jonas (3)
Basu, Samar (3)
Nyman, Ulf (3)
Gunnarsson, Iva (2)
Svenungsson, Elisabe ... (2)
Lipcsey, Miklós (2)
Lundberg, Ingrid E. (2)
Lindström, Veronica (2)
Axelsson, Ove (2)
Simard, Julia F (2)
Helmersson, Johanna (2)
Shlipak, Michael G. (2)
Hansson, Magnus (1)
Wadström, Jonas (1)
Nilsson, Ingela (1)
Fromell, Karin (1)
Carlsson, Lena (1)
Malm, Johan (1)
Hallberg, Pär (1)
Sterner, Gunnar (1)
Akerstedt, Torbjörn (1)
Axelsson, John (1)
Wallentin, Lars (1)
Lindahl, Bertil (1)
Jernberg, Tomas (1)
Melhus, Håkan (1)
James, Stefan (1)
Simonsson, Per (1)
Larsson, Anders, Pro ... (1)
Öhman, Marie (1)
Elmgren, Anders (1)
Caldwell, Karin (1)
Sjölin, Jan (1)
Mårtensson, Johan (1)
Christensson, Anders (1)
Bell, Max (1)
Schneider, Karin (1)
Biglarnia, Alireza (1)
Zegers, Ingrid (1)
Sjöström, Per (1)
Bökenkamp, Arend (1)
Pettersson, Susanne (1)
Blirup, Soren (1)
Helmersson-Karlqvist ... (1)
visa färre...
Lärosäte
Uppsala universitet (37)
Karolinska Institutet (6)
Lunds universitet (3)
Stockholms universitet (1)
Språk
Engelska (35)
Svenska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (12)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy